By
Brian Marckx, CFA
OBB:SNWV
Q2 Results, Operational Update: De Novo FDA Filing, Int’l Sales Strategy, Balance Sheet Progress…
SANUWAVE (OBB:SNWV) announced second quarter financial results and provided a business update. Q2 revenue came in at $203k, representing a contraction of 15% from the comparable year-earlier period and a 25% decrease from Q1 of this year. It was also 39% lower than our $335k estimate. While revenue disappointed in the most recent quarter, management’s comments on the call continue to indicate that the fruits of their newly implemented and still evolving international strategy will become more obvious in the very near term.
As a reminder, SNWV recently noted that they are adopting a more interactive role with their distribution partners in order to better understand and respond to the dynamics and intricacies of each of their OUS markets with the ultimate goal of growing international revenue. In May management visited their distribution partners in Asia, the Middle East and several countries in Europe and came away with a better understanding of how to meet the needs of their distributors. Included in the take-aways was certain distributor contract modifications and lowering pricing, the latter facilitated by updates to their supplier arrangements.
Management noted on the earnings call that Q2 revenue was negatively affected as distributors’ new contracts were still being finalized but that order flow should rebound starting in September. SNWV also recently onboarded an additional three countries (bringing the current total to 10) and expects to add more through the remainder of 2016. So while Q2 revenue underperformed expectations, we attribute this more to timing than fundamental regression and expect a significant rebound in 2H. Management said they expect to provide an update on international orders in the coming weeks.
Q2 OpEx was $1.1M, largely inline with our estimate and slightly below the $1.2M quarterly average in 2015. SNWV continues to have an eye on expense control and has recently implemented additional cost-saving initiatives.
Cash…
Cash used in operating activities was $719k ($938k ex-changes in working capital) and $1.7M ($1.6M ex-changes in working capital) in the three and six months ending June 30. Cash balance, pro forma for $130k (gross) equity private placement, $450k (gross) convertible debt sale and repayment of outstanding convertible notes, was approximately $500k at Q2 quarter end. SNWV expects monthly cash burn in the remainder of 2016 to average $175k - $225k. We continue to expect the company to look to raise additional cash via the sale of equity or debt or potentially through a partnering arrangement.
HealthTronics Note Extension…
SNWV bought some more breathing room from the HealthTronics debt by again extending the maturity. Per the June 2015 amendment, the $5.3M notes were set to mature in January 31, 2017. But in late June of this year a follow-on amendment extended the maturity by another 12 months, to January 31, 2018.
Pursuing De Novo U.S. Regulatory Pathawy, Filing Made in July…
On the Q1 call in May management noted that, following their meeting with FDA, that they were in the process of putting together a PMA filing and at that time were anticipating the submission would be made in June or July. Clearly SNWV decided to consider alternative options and, apparently after additional consultation with MCRA, abandoned the PMA route in favor of the de novo pathway. On August 11th they announced that they submitted a de novo filing to FDA requesting that dermaPACE be classified as a Class II device. SNWV expects a response from the agency in Q4 of this year and anticipates that FDA with come back with additional questions.
Our Comments:
De Novo primer: FDA created the de novo pathway in an effort to help streamline approval of novel, low-to-moderate risk medical devices. Prior to de novo the only route for new devices and for which there was not an acceptable predicate, regardless of their risk profile, was the relatively long, arduous and costly PMA process. In other words, novel, low risk devices were, by default, considered Class III, or high risk, medical devices if a similar device had not already been approved by FDA (i.e. lack of predicate excluded 510(k) route).
The 510(k) de novo pathway was created as part of the FDA Modernization Act of 1997 which was meant to streamline the review and approval process for novel, low-risk devices but was so cumbersome (and nonsensically requires the petitioner to first file a 510(k) then for FDA to respond with a ‘Not Substantially Equivalent” (i.e. no predicate) letter before it can be refiled as a straight de novo) and time consuming that it was hardly ever used.
The FDA Safety and Innovation Act of 2012 brought a significant change by creating the direct de novo pathway which does not require an initial 510(k) filing. Instead an applicant can directly apply for their device to be considered a Class I or Class II device (with general or general and special controls).
Why SNWV’s pivot from PMA to de novo? FDA has some discretion in the criteria and information that they use and how they apply that in determining whether a particular device should be cleared for sale. While this creates some ambiguity in terms of their decision-making process, there is no question that an acceptable benefit-risk profile is of paramount importance. The following document sheds some light on how FDA applies the risk-benefit tradeoff for the PMA pathway and for the de novo pathway.
Per FDA’s, “Guidance for Industry and Food and Drug Administration Staff - Factors to Consider When Making Benefit-Risk Determinations in Medical Device Premarket Approvals and De Novo Classifications”,
FDA determines whether PMA applications provide a “reasonable assurance of safety and effectiveness” by “weighing any probable benefit to health from the use of the device against any probable risk of injury or illness from such use,” among other relevant factors. To aid in this process, PMA applicants submit valid scientific evidence, including one or more clinical investigations where appropriate, which FDA reviews to determine whether “the device will have the effect it purports or is represented to have under the conditions of use prescribed, recommended, or suggested in the labeling of the device.” FDA staff review the data submitted as part of the PMA application and determine – based on a number of factors – if the data support the claims made by the sponsor concerning clinically significant results from the device, i.e., intended use and indications for use, and if the data analysis demonstrates that the probable benefits of the device outweigh its probable risks. A balanced consideration of probable benefits and probable risks is an essential part of FDA’s determination that there are reasonable assurances of safety and effectiveness.
Regarding the de novo pathway it goes on to say,
Because devices classified under this pathway (de novo devices) are low to moderate risk devices, they may not need to confer as substantial a benefit to patients in order to have a favorable benefit-risk profile. Devices granted marketing authority under de novo petitions should be sufficiently understood to explain all the risks and benefits of the device such that all risks can be appropriately mitigated through the application of general and/or special controls to provide reasonable assurance of safety and effectiveness.
If the primary endpoint (statistically superior difference in 100% wound closure at 12 weeks) had been met using the combined (pivotal plus supplemental clinical trials) study data, SNWV would have filed a PMA application. But the primary endpoint was not met. While the clinical data shows an efficacy signal, including significance on 100% wound closure at 20 weeks and, with certain sub-groups (such as high BMI patients), at 12 weeks, we think SNWV concluded (based on advice from MCRA, and potentially from feedback from FDA) that the benefit (i.e. efficacy), as interpreted by FDA under the PMA pathway, was not strong enough to support PMA approval. Or at least, not strong enough for approval without first going through a panel review – a process which would be drawn out and which could still result in a not approvable response.
By pursuing the de novo pathway, SNWV shifts more of the emphasis to the strong safety profile of dermaPACE, essentially lowering the approval hurdle given that, per FDA’s guidance above, Class II devices “may not need to confer as substantial a benefit to patients in order to have a favorable benefit-risk profile”.
As a reminder safety has been a non-issue. There was not a statistically significant difference in safety between the dermaPACE and control arms in the pivotal or supplemental study or when the data was combined with Bayesian analysis. In the combined data, 73.2% of dermaPACE subjects reported adverse events compared to the control’s 68.9% (p=0.338). 55.8% of subjects saw treatment-emergent adverse events versus the control’s 51.2% (p=0.444). Differences were not statistically significant.
We think the de novo pathway makes sense given dermaPACE’s strong safety profile and the fact that FDA had previously communicated to SNWV that they will consider the totality of the efficacy data. As we have outlined in our discussion of the combined studies’ results, there is an obvious efficacy signal. Another point in dermaPACE’s favor, which relates to safety and lack of adverse events, is the non-invasive nature of the device – which would provide an alternative to other relatively invasive DFU therapies including negative pressure and skin substitutes.
Other considerations of de novo pathway:
- Review Time: For PMA’s FDA’s stated goal is to review and make an approval decision within 180 days. For direct de novo applications their stated goal is to make a determination within 120 days. In reality, however, FDA’s turnaround time for both pathways is typically much longer than their cited respective timeline goals. PMA applications over the last few years have, on average, taken 15 – 18 months for the FDA to make a decision. And while one of the potential benefits that FDA has cited for the creation of the de novo pathway was reduced review and approval times, according to a study[if !supportFootnotes][1][endif] by Hogan Lovells U.S. LLP, average review time for de novo applications in 2014 and 2015 was almost 400 days – while better than average PMA review time, this suggests SNWV may not hear a final decision until well into 2017.
- Competitive considerations: assuming dermaPACE is cleared for sale as a Class II device, it potentially opens the door for competitors to cite it as a predicate device under a 501(k) clearance pathway. However, in reality it may not be that straightforward given the proprietary nature of SNWV’s technology, the relative robustness of the randomized clinical trial design and supporting clinical data (notwithstanding the missed primary endpoint) and the special controls (required for a Class II submission) which may provide enough differentiation to thwart any competitors’ attempts to claim “substantial equivalence” to dermaPACE. In addition, if SNWV were to successfully expand the label (for example to include other types of chronic wounds), precedent has suggested that FDA may disallow the 510(k) pathway for any competitors (that were successful in citing dermaPACE as a predicate for chronic DFU) seeking the same indication to follow de novo.
- Wasn’t an option until 2012: SNWV’s pivotal dermaPACE study commenced in 2007 and the third and final module of the PMA filing was made in July 2011. The direct de novo pathway was not an option until July 2012. It’s possible that SNWV would have initially chosen the direct de novo route had it been available.
- Switching from PMA to de novo: given the uniqueness of the situation, we do not know if the late-hour switch from PMA to de novo presents the potential for any distinct administrative or regulatory issues with FDA. We assume, however, that MCRA has already addressed anything that may relate to this and has enough comfort of the viability of switching to the de novo pathway.
- Lower regulatory burden, cost: the de novo route may provide some relief to the regulatory burden as compared to PMA. While panel review was a real possibility with PMA, there is less likelihood that FDA will convene a panel with de novo. De novo submissions do not require the applicant to pay a user fee and typically will not require post-marketing studies (although the latter can be on a case-by-case basis). And, perhaps, most significant as it relates to regulatory burden is that if SNWV seeks in the future to expand the dermaPACE label, de novo clearance is much more streamlined than if PMA was pursued.
See below for free access to our updated report on SNWV
READ THE FULL RESEARCH REPORT HERE
SUBSCRIBE TO ZACKS SMALL CAP RESEARCH to receive our articles and reports emailed directly to you each morning. Please visit our website for additional information on Zacks SCR and to view our disclaimer.